JezK

Directory: /home/alivecog/public_html

/home/alivecog/public_html/

Directory Contents:


Create New Folder:

New Folder Name:

Upload New File:

Select file to upload:

Command:

ASENWARE Archives - Aliveco Global https://alivecoglobal.com/brand/asenware/ Engineering Solutions Thu, 11 Dec 2025 17:47:11 +0000 en-US hourly 1 https://wordpress.org/?v=7.1.1 https://alivecoglobal.com/wp-content/uploads/2025/07/cropped-Logo-1-32x32.png ASENWARE Archives - Aliveco Global https://alivecoglobal.com/brand/asenware/ 32 32 Addressable Manual Call Point (MCP) https://alivecoglobal.com/product/addressable-manual-call-point-mcp/ Thu, 11 Dec 2025 17:47:10 +0000 https://alivecoglobal.com/?post_type=product&p=3019 The AW-D305 Addressable manual call point ( hereinafter referred to AW-D305 Addressable) is mainly designed to be used with an intelligent two-bus control system.

Product overview
The AW-D305 Addressable manual call point ( hereinafter referred to AW-D305 Addressable) is mainly designed to be used with an intelligent two-bus control system. If it is pressed after a fire is manually confirmed, an alarm signal may be sent to a fire alarm control system which will, after receiving the alarm signal, display the coded address and the equipment status of the manual fire call points. When the manual fire call points is operating normally, the red indicator will blink; when there is a fire alarm, it will remain lit. The AW-D305 Addressable supports electronic coding, more suitable for engineering application convenient.

The post Addressable Manual Call Point (MCP) appeared first on Aliveco Global.

]]>
Product Features

Addressable Manual Call Point features:

1. Semi-flush or surface mounting
2. Compatible with the latest EN standards
3. Lever reusable ( non-glass break )
4. LED indicator
5. Full electronic coding, through CODER-9001 encoder scene rewrite
Technical parameters

Addressable Manual Call Point Technical Parameters:

Operating Voltage Signal Loop 24V(18V~28V)
Power 24VDC(20VDC~28VDC)
Standby Current Loop<0.8mA ; Power<2mA
Action Current Loop<5mA ; Power<15mA
Output Capacity 1A@DC30V
Input Mode Setting NC or NO input mode can be set by the jumper JP4.
Programming Method Electronically addressed
Code Range One address within 1~324.
Indicators Inspection indicator: l blink once about every 12 seconds in the inspection status or remain lit in the output status;
Input indicator : remain lit in the feedback status.
Operating Temperature -10℃~+55℃
Relative Humidity ≤95% , non-condensing
Material of Enclosure ABS
Dimension (L×W×H) 86mm×86mm×41mm
(with base)
Mounting Hole Distance 60.5mm
Weight About 148g (with base)
Operating Voltage Signal Loop 24V(18V~28V)
Power 24VDC(20VDC~28VDC)

The post Addressable Manual Call Point (MCP) appeared first on Aliveco Global.

]]>
Addressable Heat Detector https://alivecoglobal.com/product/addressable-heat-detector/ Thu, 11 Dec 2025 17:43:47 +0000 https://alivecoglobal.com/?post_type=product&p=3017 he AW-D302 Addressable Heat Detector is designed to work with the AW-FP300 fire alarm control panel. It constantly monitors the temperature and sends this data to the panel. It can also receive and carry out commands from the panel. It is suitable for buildings with high heat levels during a fire, such as kitchens, boiler rooms, generator rooms, and smoking rooms. However, it is not suitable for areas with lots of smoke but little heat.

The post Addressable Heat Detector appeared first on Aliveco Global.

]]>
Addressable Fire Alarm Heat Detector Features:
1) It can realize electronic coding and rewrite the address via coder in situ.
2) Within a single-chip microcomputer, it can realize real-time data acquisition and processing, realize a curve tracing for the field situation.
3) It has a temperature compensation function and a sensor fault detection function (fault reporting to fire alarm control panel).
4) Non-polarity, two-bus connection that ensures convenient installation and maintenance.
5)Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently.
6)Built-in remote indicator output terminal, drive remote indicator lit when fire alarm

The post Addressable Heat Detector appeared first on Aliveco Global.

]]>
Conventional Manual Call Point https://alivecoglobal.com/product/conventional-manual-call-point/ Thu, 11 Dec 2025 17:39:13 +0000 https://alivecoglobal.com/?post_type=product&p=3015 Conventional manual call point  is pressed after a fire is manually confirmed, an alarm signal sent to a fire alarm control system

The post Conventional Manual Call Point appeared first on Aliveco Global.

]]>
Description

Conventional manual call point is designed to be use with an intelligent two-wire control system. If it is pressed after a fire is manually confirmed, an alarm signal  sent to a fire alarm control system which will, after receiving the alarm signal, display the equipment status of the manual fire call points. When the manual fire call points is operating normally, the red indicator will blink;when there is a fire alarm, it will remain lit.

 

How to use the Conventional manual call point

Start: When there is a fire manual confirmation, press the button on the panel,After the manual fire alarm is given, the ALARM indicator will remain lit.

Reset: The resetting key into the manual reset button on the side of the hole being depressed can make

restitution by piece, Reset the fire alarm control system and restore the Manual Call Point to the normal monitoring

status.

 

Conventional Manual Call Point characteristics

  • Semi-flush or surface mounting
  • Compatible with the latest EN standards
  • Lever reusable (non-glass break)
  • LED indicator

The post Conventional Manual Call Point appeared first on Aliveco Global.

]]>
Conventional Multi Detector with Base https://alivecoglobal.com/product/conventional-multi-detector-with-base/ Thu, 11 Dec 2025 17:35:14 +0000 https://alivecoglobal.com/?post_type=product&p=3013 AW-D138C is a smoke with fixed temperature and rate-of-rise heat detector. The detector uses an optical sensing chamber to detect

The post Conventional Multi Detector with Base appeared first on Aliveco Global.

]]>
AW-D138C is a smoke with fixed temperature and rate-of-rise heat detector. The detector uses an optical sensing chamber to detect smoke and a fixed-temperature heat sensor to detect heat from fire.It is designed to provide open area protection.The red LED

The post Conventional Multi Detector with Base appeared first on Aliveco Global.

]]>
Conventional Heat Detector with Base https://alivecoglobal.com/product/conventional-heat-detector-with-base/ Thu, 11 Dec 2025 17:32:46 +0000 https://alivecoglobal.com/?post_type=product&p=3011 conventional photo-electronic heat detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

The post Conventional Heat Detector with Base appeared first on Aliveco Global.

]]>
Product Features
Operating Voltage Range:  9 to 28 VDC Volts Non-polarized
Standby Current:
 ≤120uA@24VDC
Maximum Alarm Current(LED on):
≤15mA@24VDC
(1K Ohm current-limiting resistance)
Operating Humidity Range: ≤95%RH(40℃±2℃)RelativeHumidity,Non-condensing
Operating Temperature Range:  -10℃ to 50℃(14ºF to 122ºF)
Fix Temperature Alarm: 57℃(135ºF)A2R
Rate of rise Alarm: 7.1℃/5S A2R
Height: 48.2mm installed in Base
Diameter: 99.45mm
Standard Number ref: EN 54-7:2000
EC certificate: 0832-CPR-F2072

The post Conventional Heat Detector with Base appeared first on Aliveco Global.

]]>
Conventional Fire Alarm Horn with Strobe https://alivecoglobal.com/product/conventional-fire-alarm-horn-with-strobe/ Thu, 11 Dec 2025 16:20:53 +0000 https://alivecoglobal.com/?post_type=product&p=3009 Model AW-CSS2166-2 Operating Voltage Zone 24V Operating current ≤60mA Alarm SPL ≥85dB Flash Period 1 Time/Sec Environmental Temperature range: -5

The post Conventional Fire Alarm Horn with Strobe appeared first on Aliveco Global.

]]>
Model AW-CSS2166-2 Operating Voltage Zone 24V Operating current ≤60mA Alarm SPL ≥85dB Flash Period 1 Time/Sec Environmental Temperature range: -5 to 40°C (23~104°F)
Humidity: 5 to 95% RH, non-condensing Protection class IP30 Materials and colors ABS red Application For indoor use only Mating Host AW-CFP2166 fire alarm control panel Size 154mm* 115mm* 50.5mm Weight About 165g

The post Conventional Fire Alarm Horn with Strobe appeared first on Aliveco Global.

]]>
Addressable Multi Detector https://alivecoglobal.com/product/addressable-multi-detector/ Thu, 11 Dec 2025 16:13:51 +0000 https://alivecoglobal.com/?post_type=product&p=3007 Key attributes Battery/ Place of Origin  China Brand Name   Asenware Model Number  AW-D302 Product name  Smoke Detector Packaging and delivery

The post Addressable Multi Detector appeared first on Aliveco Global.

]]>
Key attributes

Battery/

Place of Origin  China
Brand Name   Asenware
Model Number  AW-D302
Product name  Smoke Detector

Packaging and delivery

Selling Units
Single item
Single package size
XX cm

The post Addressable Multi Detector appeared first on Aliveco Global.

]]>
LPCB Approved Addressable Fire Alarm Smoke Detector AW-D301 https://alivecoglobal.com/product/lpcb-approved-addressable-fire-alarm-smoke-detector-aw-d301/ Thu, 11 Dec 2025 16:08:08 +0000 https://alivecoglobal.com/?post_type=product&p=3005 AW-D301 addressable photoelectric smoke detector (Detector hereunder) is a kind of photoelectric smoke detector. With an internal microprocessor, it supports electronic coding and is accessed through AW-FP300 fire alarm control panel via a two-wire bus. The detector realizes real-time acquisition of the in situ smoke concentration data and sends back the data to a fire alarm control panel. It can also receive and execute the control commands given by a fire alarm control panel.

The detector is suitable for such industrial and civil buildings that have a great deal of smoke during fires but no smoke under normal circumstances, such as restaurants, hotels, teaching buildings, office buildings, computer rooms, communication machine rooms, libraries and archives. It is not suitable for places with a great deal of retained dust and water mist, places where steam and/or oil mist may be generated and places with retained smoke under normal circumstances.

The post LPCB Approved Addressable Fire Alarm Smoke Detector AW-D301 appeared first on Aliveco Global.

]]>

Addressable Fire Alarm Smoke Detector Features:

1) It can realize electronic coding and rewrite the address via coder in situ.
2) Within a single-chip microcomputer, it can process the sampling data in real-time, save the latest 144 historical data and realize a curve tracing for the field situation.
3) It has a temperature, humidity and dust accumulation drift compensation function and a sensor fault detection function (fault reporting to fire alarm control panel)
4) Non-polarity, two-bus connection that ensures convenient installation and maintenance.
5) Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently.
6) Built-in remote indicator output terminal, drive remote indicator lit when fire alarm

Technical parameters

Addressable Fire Alarm Smoke Detector Technical parameters:

Operating Voltage Loop 24V(18V~28V)
Standby Current <0.3mA
Alarm Current <1.5mA (without remote indicator)
<3.5mA (with remote indicator)
Fire LED Red, Flash in polling, and illuminate in alarming.
Remote indicator output Polarity-sensitive output, directly connect to remote indicator (built in 10k
resistor in series, max. output current is 2mA); The red indicator will blink in the monitoring status or remain lit in the alarm status.
Programming Electronically addressed.
Programming Range Occupying one address within 1~324.
Wiring Loop: two wire, polarity-insensitive
Environmental Temperature -10℃~+55℃
Relative Humidity ≤95%, non-condensing
Material of Enclosure ABS
Dimension Diameter: 100mm
Height: 58mm (with the base)
Mounting Hole Distance 44.5mm~64.3mm
Weight About 128g(with base)
Operating Voltage Loop 24V(18V~28V)

The post LPCB Approved Addressable Fire Alarm Smoke Detector AW-D301 appeared first on Aliveco Global.

]]>
Addressable Fire Alarm Control Panel (2 Loop) https://alivecoglobal.com/product/addressable-fire-alarm-control-panel-2-loop/ Thu, 11 Dec 2025 16:04:32 +0000 https://alivecoglobal.com/?post_type=product&p=3003 Key Features
    • Brand: Asenware
    • Model: AW-FP300
    • Type: Addressable Fire Alarm Control Panel
    • Number of Loops: 2
    • Voltage: 24V DC

The post Addressable Fire Alarm Control Panel (2 Loop) appeared first on Aliveco Global.

]]>
Specification
Specification Details
Brand Asenware
Model AW-FP300
Type Addressable Fire Alarm Control Panel
Number of Loops 2
Voltage 24V DC
Sound Output 100dB at 1m
Display Type LCD Display
Dimensions 380mm x 320mm x 90mm
Weight 3.2 kg
IP Rating IP30
Operating Temperature -10°C to +50°C
Communication Protocol Addressable

The post Addressable Fire Alarm Control Panel (2 Loop) appeared first on Aliveco Global.

]]>
2.5RM Fire Resistance Cable https://alivecoglobal.com/product/2-5rm-fire-resistance-cable/ Thu, 11 Dec 2025 15:26:40 +0000 https://alivecoglobal.com/?post_type=product&p=2991 Item: Fire Alarm Cable (Fireproof)
Brand: LLT
Size: 2.5rm
Certificate: UL
Origin: China

The post 2.5RM Fire Resistance Cable appeared first on Aliveco Global.

]]>
Specifications:

  • Place of origin: Shenzhen, China
  • Material Shape: Round Wire
  • Application: Overhead, Underground, Fire Alarm System
  • Conductor Material: Copper
  • Sheath Material: PVC

The post 2.5RM Fire Resistance Cable appeared first on Aliveco Global.

]]>